THD + N
THD+N = √(Vharm² + Vnoise²) / V1
Quick answer
This calculator solves THD+N = √(Σharmonics² + Σnoise²) / V1 for THD + N. With Harmonic RMS 0.6 V, Noise RMS 1.32 V, Fundamental RMS 12 V, the result is 12.08 %. It solves in 4 directions, so you can enter the values you have and get the one you need.
Calculator
Formula
Description
Total harmonic distortion plus noise combines all the harmonic distortion products and the broadband noise into a single fidelity figure, referenced to the fundamental. It is the most common audio and signal-chain quality metric because it captures everything that is not the wanted signal. Over the full bandwidth, THD+N is equivalent to SINAD expressed as a ratio rather than in decibels.
Variables
- THD+N — Total distortion + noise ratio (fraction)
- Vharm — RMS sum of harmonic components (V)
- Vnoise — RMS noise (V)
- V1 — Fundamental RMS amplitude (V)
Practical Notes
In dB, THD+N = 20·log10(ratio) and SINAD = −THD+N(dB). A 0.001% THD+N (−100 dB) is excellent audio performance; measurement bandwidth strongly affects the noise term.
Symbols and units
| Symbol | Meaning | Default unit | Accepted units |
|---|---|---|---|
| THDN | THD + N | % | —, % |
| Vharm | Harmonic RMS | mV | pV, nV, µV, mV, V, kV |
| Vnoise | Noise RMS | mV | pV, nV, µV, mV, V, kV |
| V1 | Fundamental RMS | V | pV, nV, µV, mV, V, kV |
Step by step
- 1. What you know: Harmonic RMS 0.6 V, Noise RMS 1.32 V, Fundamental RMS 12 V
- 2. The relation: THD+N = √(Σharmonics² + Σnoise²) / V1
- 3. Substitute: Vharm = 0.6 V, Vnoise = 1.32 V, V1 = 12 V
- 4. Result: THD + N = 12.08 %
Worked examples
Minimum range
Given: Harmonic RMS 10 mV, Noise RMS 22 mV, Fundamental RMS 0.33 V
Result: THD + N = 7.323 %
Low range
Given: Harmonic RMS 100 mV, Noise RMS 0.22 V, Fundamental RMS 3.3 V
Result: THD + N = 7.323 %
Typical
Given: Harmonic RMS 0.6 V, Noise RMS 1.32 V, Fundamental RMS 12 V
Result: THD + N = 12.08 %
High range
Given: Harmonic RMS 0.9 V, Noise RMS 1.98 V, Fundamental RMS 0.23 kV
Result: THD + N = 0.9456 %
Maximum range
Given: Harmonic RMS 9 V, Noise RMS 19.8 V, Fundamental RMS 2.3 kV
Result: THD + N = 0.9456 %
Solving for each variable
Solve for THD + N
Harmonic RMS 10 mV, Noise RMS 22 mV, Fundamental RMS 0.33 V → 7.323 %
Solve for Fundamental RMS
THD + N 0.5 %, Harmonic RMS 10 mV, Noise RMS 22 mV → 4.833 V
Solve for Harmonic RMS
THD + N 500 %, Noise RMS 22 V, Fundamental RMS 0.33 kV → 1.65 kV
Solve for Noise RMS
THD + N 500 %, Harmonic RMS 10 V, Fundamental RMS 0.33 kV → 1.65 kV
How THD + N changes with Harmonic RMS
| Harmonic RMS (input) | THD + N (result) |
|---|---|
| 60 mV | 11.01 % |
| 150 mV | 11.07 % |
| 0.3 V | 11.28 % |
| 0.45 V | 11.62 % |
| 0.6 V | 12.08 % |
| 0.9 V | 13.31 % |
| 1.2 V | 14.87 % |
| 2.4 V | 22.83 % |
| 4.2 V | 36.69 % |
| 6 V | 51.2 % |
The same result in other units
| Unit | Value |
|---|---|
| % | 0.1208 |
| % | 12.08 |
Embed this calculator
Paste this into any page. It keeps working when this page updates, and credits the source.
<iframe src="https://vbatpower.com/embed/thd-plus-noise/" width="100%" height="460" style="border:1px solid #1f2a37;border-radius:12px" loading="lazy" title="THD + N"></iframe>
<p><a href="https://vbatpower.com/formulas/thd-plus-noise/">THD + N</a> Calculator by vbatpower.com</p> Frequently asked questions
How do you calculate THD + N?
Use THD+N = √(Σharmonics² + Σnoise²) / V1. With Harmonic RMS 0.6 V, Noise RMS 1.32 V, Fundamental RMS 12 V, THD + N works out to 12.08 %.
What is the formula for THD + N?
The formula is THD+N = √(Σharmonics² + Σnoise²) / V1. Total harmonic distortion plus noise combines all the harmonic distortion products and the broadband noise into a single fidelity figure, referenced to the fundamental.
How do you find Fundamental RMS when you know the other values?
Rearrange for Fundamental RMS: with THD + N 0.5 %, Harmonic RMS 10 mV, Noise RMS 22 mV, Fundamental RMS is 4.833 V.
How do you find Harmonic RMS when you know the other values?
Rearrange for Harmonic RMS: with THD + N 500 %, Noise RMS 22 V, Fundamental RMS 0.33 kV, Harmonic RMS is 1.65 kV.
What units does THD + N use?
THD + N is shown in %, %. Values are held in SI base units internally, so you can mix prefixes without converting by hand.
Related Concepts
All Signal & dB formulas →Need more features?
Save calculations, import telemetry data, simulate battery discharge, and collaborate with your team.
Try the App